Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.17/1971
Título: Environment and Health in Children Day Care Centres (ENVIRH) - Study Rationale and Protocol
Autor: Araújo-Martins, J
Carreiro-Martins, P
Viegas, J
Aelenei, D
Cano, MM
Teixeira, JP
Paixão, P
Papoila, AL
Leiria-Pinto, P
Pedro, C
Rosado-Pinto, J
Annesi-Maesano, I
Neuparth, N
Palavras-chave: Poluição do Ar em Ambientes Fechados
Creches
Sistema Respiratório
Ventilação de Edificios
Doenças Respiratórias
Criança
HDE CINV
HDE ALER
Data: 2014
Editora: Elsevier España
Citação: Rev Port Pneumol. 2014;20(6):311-323
Resumo: Background: Indoor air quality (IAQ) is considered an important determinant of human health. The association between exposure to volatile organic compounds, particulate matter, house dust mite, molds and bacteria in day care centers (DCC) is not completely clear. The aim of this project was to study these effects. Methods --- study design: This study comprised two phases. Phase I included an evaluation of 45 DCCs (25 from Lisbon and 20 from Oporto, targeting 5161 children). In this phase, building characteristics, indoor CO2 and air temperature/relative humidity, were assessed. A children’s respiratory health questionnaire derived from the ISAAC (International Study on Asthma and Allergies in Children) was also distributed. Phase II encompassed two evaluations and included 20 DCCs selected from phase I after a cluster analysis (11 from Lisbon and 9 from Oporto, targeting 2287 children). In this phase, data on ventilation, IAQ, thermal comfort parameters, respiratory and allergic health, airway inflammation biomarkers, respiratory virus infection patterns and parental and child stress were collected. Results: In Phase I, building characteristics, occupant behavior and ventilation surrogates were collected from all DCCs. The response rate of the questionnaire was 61.7% (3186 children). Phase II included 1221 children. Association results between DCC characteristics, IAQ and health outcomes will be provided in order to support recommendations on IAQ and children’s health. A building ventilation model will also be developed. Discussion: This paper outlines methods that might be implemented by other investigators conducting studies on the association between respiratory health and indoor air quality at DCC.
Peer review: yes
URI: http://hdl.handle.net/10400.17/1971
Aparece nas colecções:ALER - Artigos
CINV - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Rev Port Pneumol 2014_311.pdf337,47 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.