Título: CO2 Concentration in Day Care Centres is Related to Wheezing in Attending Children
Autor: Carreiro-Martins, P
Viegas, J
Papoila, AL
Aelenei, D
Caires, I
Araújo-Martins, J
Gaspar-Marques, J
Cano, MM
Mendes, AS
Virella, D
Rosado-Pinto, J
Leiria-Pinto, P
Annesi-Maesano, I
Neuparth, N
Palavras-chave: Indoor Air Quality
Child Day Care Centers
Ventilation
Environmental Health
Child
HDE ALER
HDE CINV
Data: 2014
Editora: Springer-Verlag
Citação: Eur J Pediatr. 2014; 173:1041–1049
Resumo: Poor ventilation at day care centres (DCCs) was already reported, although its effects on attending children are not clear. This study aimed to evaluate the association between wheezing in children and indoor CO2 (a ventilation surrogate marker) in DCC and to identify behaviours and building characteristics potentially related to CO2. In phase I, 45 DCCs from Lisbon and Oporto (Portugal) were selected through a proportional stratified random sampling. In phase II, 3 months later, 19 DCCs were further reassessed after cluster analysis for the greatest difference comparison. In both phases, children’s respiratory health was assessed by ISAAC-derived questionnaires. Indoor CO2 concentrations and building characteristics of the DCC were evaluated in both phases, using complementary methods. Mixed effect models were used to analyze the data. In phase I, which included 3,186 children (mean age 3.1±1.5 years), indoor CO2 concentration in the DCC rooms was associated with reported wheezing in the past 12months (27.5 %) (adjusted odds ratio (OR) for each increase of 200 ppm 1.04, 95 % CI 1:01 to 1:07). In phase II, the association in the subsample of 1,196 children seen in 19 out of the initial 45 DCCs was not significant (adjusted OR 1.02, 95 % CI 0.96 to 1.08). Indoor CO2 concentration was inversely associated with the practices of opening Windows and internal doors and with higher wind velocity. A positive trend was observed between CO2 and prevalence of reported asthma (4.7 %). Conclusion: Improved ventilation is needed to achieve a healthier indoor environment in DCC.
Peer review: yes
URI: http://hdl.handle.net/10400.17/1919
Aparece nas colecções:ALER - Artigos
CINV - Artigos

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Eur J Pediatr 2014_173_1041.pdf183,37 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.